Home > Robot Battery > Medical Robot Battery > 25.2V 2.9Ah Li-ion Battery for Medical Rehabilitation Robot

25.2V 2.9Ah Li-ion Battery for Medical Rehabilitation Robot

25.2V 2.9Ah Li-ion Battery for Medical Rehabilitation Robot: 2900mAh capacity, -20~50℃ tolerance. Powers electric rehab bots, patient-assist devices—safe, reliable healthcare power.

  • Nominal Voltage:25.2V
  • Rated Capacity:2900mAh
  • Dimension:100*80*45mm
  • Charge Voltage:29.4V
  • Charge Current:≤3A
  • Discharge Current:3A
  • Discharge Cut-off Voltage:19.6V
  • Weight:650g
  • Operating Temperature:-20~50℃
  • Application:Medical rehabilitation robot

25.2V 2.9Ah Li-ion Battery for Medical Rehabilitation Robot | Precision Power for Healthcare Robotics

Introduction

Engineered for therapeutic precision, the 25.2V 2.9Ah Li-ion Battery for Medical Rehabilitation Robot delivers stable performance, multi-layer safety, and 2900mAh endurance. As a critical Battery for Medical Rehabilitation Robot, it integrates high-density Li-ion cells, 25.2V output, and wide temperature tolerance—ideal for electric rehab bots, patient-assist devices, and clinical therapy systems.

 

Medical Robot Lithium Battery Model Comparison Table

Battery Model Voltage Capacity Battery Type Medical Robot Applications Key Features
18650 39.6V 13.4Ah Li – ion Battery 39.6V 13400mAh (13.4Ah) 18650 Li – ion Electric rehab robots, medical assist devices High energy density; – 20~60℃ operating temp; stable 39.6V output for motors/sensors
18650 48V 6.7Ah Li – ion Battery 48V 6700mAh (6.7Ah) 18650 Li – ion Leg/upper – limb rehab robots Stable 48V power; multi – layer safety (short – circuit/overcharge protection); compact design
25.2V 2.9Ah Li – ion Battery 25.2V 2900mAh (2.9Ah) Li – ion Small rehab robots, patient transfer bots Lightweight; 6 + hours runtime; – 20~50℃ temp resilience; fits compact medical devices
Panasonic 18650 36V 20Ah NMC Battery 36V 20100mAh (20.1Ah) NMC Patrol – style medical robots, ward service bots RS485 communication for real – time monitoring; 20Ah high capacity; 500 + cycles

Why This Li-ion Battery Dominates Medical Rehabilitation

1. Stable Power for Therapeutic Devices

The 25.2V 2.9Ah Li-ion Battery for Medical Rehabilitation Robot ensures:
  • “25.2V Consistent Output: Drives precise motor functions in leg/arm rehab robots, ensuring smooth therapy delivery.”
  • “2900mAh Long Runtime: Supports 4+ hours of continuous patient-assist device use—no mid-session interruptions.”

2. Rugged Design for Healthcare Settings

With Li-ion cells and -20~50℃ operation:
  • “Shock-Resistant Casing: Survives drops, vibrations in clinical environments—no damage to battery/device.”
  • “Wide Temp Adaptation: Works in hospital ICUs (25℃), home care (30℃), and cold storage (-20℃).”

3. Safety-Focused for Patient Care

Integrated protections (short-circuit, overcharge) provide:
  • “Multi-Layer Safety: Prevents risks in medical rehabilitation equipment—critical for patient-facing devices.”
  • “Reliable Performance: Maintains 80% capacity after 500+ cycles—low maintenance for healthcare facilities.”

Application Scenarios

1. Electric Rehabilitation Robots

The Li-ion Battery for Medical Rehabilitation Robot powers:
  • “Leg-Therapy Robots: 25.2V output supports motorized gait training, ensuring smooth stroke recovery sessions.”
  • “Upper-Limb Rehab Devices: 2900mAh capacity enables 5+ hours of continuous arm-movement therapy.”

2. Patient-Assist Robotic Systems

For clinical and home care:
  • “Transfer Assistance Robots: Stable 25.2V power ensures safe patient lifts, reducing caregiver strain.”
  • “Mobility-Aid Robots: Operates at -20℃ in cold climates, 50℃ in hot regions—no performance loss.”

FAQ

Q1: What applications are medical robot batteries designed for?

A: Medical robot batteries are used in applications such as rehabilitation robots, surgical robotic equipment, hospital logistics robots, and other mobile or electrically powered healthcare robotic systems. The battery must be matched to the robot’s voltage, runtime, load profile, available installation space, charging method, and control interface rather than selected by capacity alone.

A: Start with the robot’s required voltage, usable capacity, continuous and peak current, target runtime, available battery space, weight limit, charging requirements, and communication interface. For medical rehabilitation and surgical robotic equipment, stable power delivery and predictable integration are especially important, so the battery should be engineered around the complete operating profile of the equipment.

A: Yes. FEBATT can develop custom medical robot battery packs according to project requirements, including voltage, capacity, cell configuration, dimensions, housing, connector type, BMS settings, charging parameters, and communication interfaces. Customization is particularly useful when rehabilitation or surgical robots have restricted installation space or non-standard electrical requirements.

A: Rechargeable lithium-ion chemistries, including LiFePO4 and other lithium-ion configurations, can be used in medical robot applications. The appropriate chemistry depends on required energy density, cycle life, discharge performance, size, weight, and operating conditions. Chemistry should therefore be selected according to the specific medical robot design rather than treated as a one-size-fits-all choice.

A: A Battery Management System (BMS) monitors key battery conditions such as voltage, current, and temperature and can provide protection against overcharge, over-discharge, overcurrent, short circuit, and abnormal temperature conditions. Depending on the battery configuration, the BMS may also support state-of-charge estimation, fault information, cell balancing, and communication with the robot controller.

A: Service life depends on battery chemistry, depth of discharge, charge and discharge rate, operating temperature, charging strategy, and the robot’s duty cycle. As a reference, selected FEBATT robot battery configurations are rated for 2,000+ cycles at 80% depth of discharge (DoD). The actual cycle-life rating for a medical robot battery should always be confirmed for the selected model and operating conditions.

A: Medical robots can have different power demands during movement, lifting, actuator operation, computing, or other peak-load events. The battery must provide sufficient continuous current for normal operation and adequate peak current for short-duration load increases without excessive voltage drop or protection shutdown. These current requirements should be defined during battery selection and matched to the BMS and cell configuration.

A: Depending on the project, medical robot battery systems can be configured with communication interfaces such as CAN or RS485 for data exchange with the robot controller. These interfaces can support information such as state of charge, voltage, current, temperature, and fault status. The required protocol, message format, and communication logic should be confirmed during system integration.

A: Size and weight can directly affect robot mobility, balance, enclosure design, and serviceability. FEBATT’s published medical robot battery examples include compact configurations such as 25.2V 2.9Ah as well as higher-capacity configurations such as 22.4V 50Ah, showing that battery architecture can vary substantially by application. A custom pack should be designed around the actual installation envelope and weight target of the robot.

A: Charging current, charger voltage, target runtime, duty cycle, allowable charging window, and whether the robot charges between operating periods should all be defined before the battery is finalized. For example, one published 48V 10Ah rehabilitation robot battery specifies a charge current of up to 5A and a 10A discharge current, illustrating why charging and load requirements must be matched to the individual battery model rather than assumed across the full product range.

Ready to Partner with FEBATT?

Join hundreds of B2B partners worldwide who trust us for reliable lithium battery solutions.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Scroll to Top

Professional Battery Solution Supplier

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.